Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
J. pediatr. (Rio J.) ; 98(1): 84-91, Jan.-Feb. 2022. tab, graf
Article in English | LILACS | ID: biblio-1360548

ABSTRACT

Abstract Objective: To validate the Family Health Behavior Scale (FHBS) for Brazilian families. Methods: The sample included 272 children aged 5 to 12 years old. Caregivers and their healthy answered the FHBS and questions about physical activity. In addition, anthropometric measurements of the children's weight and height were performed, as well as the bioimpedance exam. The scale was translated and the following validities were assessed: content (qualitative analysis and content validity index), construct (factor analysis) and concurrent validity (difference between domains and the total score with the categories of BMI, fat percentage and physical activity). Reliability (Cronbach's alpha, ceiling-floor effect, two-half test, intraclass correlation and Bland - Altman) was also assessed. Results: FHBS instrument performed well with regard to the psychometric properties in the Brazilian population. The content validity index was 0.987. Fit indices of the factor analysis were considered satisfactory, according to Bartlett's sphericity test (χ 2 = 1927, df = 351; p < 0.001) and the Kaiser-Meyer-Olkin index (KMO = 0.789). Concurrent validity, the differences between the mean of the domains and the total score between the categories of BMI (p = 0.011), percentage of fat (0.004) and physical activity (p < 0.001) were all significant. The reliability results were Cronbach's alpha internal consistency = 0.83, adequate ceiling-floor effect, 0.8105 (0.09 SD) two-half test, 0.626 intraclass correlation (95% CI: 0.406 to 0.777) and Bland - Altman -0.840 (-22.76 to 21.07). Conclusion: The FHBS adapted for the Brazilian population showed evidence of adequate psychometric performance.


Subject(s)
Humans , Child, Preschool , Child , Health Behavior , Psychometrics , Brazil , Surveys and Questionnaires , Reproducibility of Results
2.
Arq. bras. cardiol ; 112(5): 491-498, May 2019. tab, graf
Article in English | LILACS | ID: biblio-1011193

ABSTRACT

Abstract Background: The use of Cardiovascular Implantable Electronic Devices (CIED), such as the Implantable Cardioverter Defibrillator (ICD) and Cardiac Resynchronization Therapy (CRT), is increasing. The number of leads may vary according to the device. Lead placement in the left ventricle increases surgical time and may be associated with greater morbidity after hospital discharge, an event that is often confused with the underlying disease severity. Objective: To evaluate the rate of unscheduled emergency hospitalizations and death after implantable device surgery stratified by the type of device. Methods: Prospective cohort study of 199 patients submitted to cardiac device implantation. The groups were stratified according to the type of device: ICD group (n = 124) and CRT group (n = 75). Probability estimates were analyzed by the Kaplan-Meier method according to the outcome. A value of p < 0.05 was considered significant in the statistical analyses. Results: Most of the sample comprised male patients (71.9%), with a mean age of 61.1 ± 14.2. Left ventricular ejection fraction was similar between the groups (CRT 37.4 ± 18.1 vs. ICD 39.1 ± 17.0, p = 0.532). The rate of unscheduled visits to the emergency unit related to the device was 4.8% in the ICD group and 10.6% in the CRT group (p = 0.20). The probability of device-related survival of the variable "death" was different between the groups (p = 0.008). Conclusions: Patients after CRT implantation show a higher probability of mortality after surgery at a follow-up of less than 1 year. The rate of unscheduled hospital visits, related or not to the implant, does not differ between the groups.


Resumo Fundamento: O uso de dispositivos cardíacos eletrônicos implantáveis (DCEI) como o cardiodesfibrilador (CDI) e terapia de ressincronização cardíaca (TRC) - é cada vez maior. O número de eletrodos de estimulação e desfibrilação varia de acordo com o dispositivo. A colocação do eletrodo no ventrículo esquerdo aumenta o tempo cirúrgico podendo associar-se a maior morbidade no acompanhamento após alta hospitalar, evento muitas vezes confundível com a gravidade da patologia base. Objetivo: Avaliar a taxa de internação não programada na emergência e óbito após cirurgia de dispositivos implantáveis estratificados pelo tipo de aparelho. Métodos: Estudo de coorte prospectivo analisando 199 pacientes submetidos à implante de dispositivos cardíacos. Os grupos foram divididos de acordo com o tipo de dispositivo: CDI (n = 124) e TRC (n = 75). Estimativas de probabilidades foram analisadas pelo método de Kaplan-Meier de acordo com o desfecho. Valor de p < 0,05 foi considerado significativo nas análises estatísticas. Resultados: A maioria da amostra era do sexo masculino (71,9%) - idade média de 61,1 ± 14,2. A fração de ejeção do ventrículo esquerdo foi similar entre os grupos (TRC 37,4 ± 18,1 vs. CDI 39,1 ± 17,0; p = 0,532). A taxa de visita não programada na emergência relacionada ao dispositivo foi de 4,8% no grupo CDI e de 10,6% no grupo TRC (p = 0,20). A probabilidade de sobrevida relacionada ao dispositivo da variável "óbito" mostrou-se diferente entre os grupos (p = 0,008). Conclusões: Paciente após o implante de TRC apresenta maior probabilidade de mortalidade após o procedimento cirúrgico no seguimento menor que 1 ano. A taxa de visita hospitalar não programada, relacionadas ou não ao implante, não difere entre os grupos.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Arrhythmias, Cardiac/therapy , Defibrillators, Implantable/statistics & numerical data , Cardiac Resynchronization Therapy Devices/statistics & numerical data , Patient Readmission/statistics & numerical data , Time Factors , Prospective Studies , Follow-Up Studies , Defibrillators, Implantable/adverse effects , Emergency Service, Hospital/statistics & numerical data , Kaplan-Meier Estimate , Cardiac Resynchronization Therapy Devices/adverse effects
3.
Arq. bras. cardiol ; 111(1): 13-18, July 2018. tab, graf
Article in English | LILACS | ID: biblio-950184

ABSTRACT

Abstract Background: Brugada syndrome (SBr) is an arrhythmic condition characterized by ST-T segment abnormalities in the right precordial leads associated with a high risk of ventricular arrhythmias and sudden death. Local data regarding the clinical characteristics of patients with a typical electrocardiographic (ECG) pattern undergoing electrophysiological study are scarce. Objective: To evaluate patients with an ECG pattern suggestive of SBr referred for electrophysiological evaluation in a specialized center. Methods: Cohort study of patients referred for electrophysiological study because of an ECG pattern compatible with SBr between January 1998 and March 2017. Results: Of the 5506 procedures, 35 (0.64%) were for SBr investigation, 25 of which (71.42%) were performed in men. The mean age was 43.89 ± 13.1 years. The ECG patterns were as follows: type I, 22 (62.85%); type II, 12 (34.30%); and type III, 1 (2.85%). Twenty-three patients (65.7%) were asymptomatic, 6 (17.14%) had palpitations, 5 (14.3%) had syncope, and 3 (8.6%) had a family history of sudden death. Electrophysiological study induced ventricular tachyarrhythmias in 16 cases (45.7%), the mean ventricular refractory period being 228 ± 36 ms. Ajmaline / procainamide was used in 11 cases (31.4%), changing the ECG pattern to type I in 7 (63.6%). Sixteen cases (45.7%) received an implantable cardioverter defibrillator (ICD). In a mean 5-year follow-up, 1 of the 16 patients (6.25%) with ICD had appropriate therapy for ventricular fibrillation. There was no death. Other arrhythmias occurred in 4 (11.4%) cases. Conclusions: Most patients are men, and a type I ECG pattern is the main indication for electrophysiological study. Class IA drugs have a high ECG conversion rate. The ICD event rate was 6%. (Arq Bras Cardiol. 2018; [online].ahead print, PP.0-0)


Resumo Fundamento: Síndrome de Brugada (SBr) é uma condição arrítmica definida por anormalidades do segmento ST-T em derivações V1-V3 associada a risco elevado de arritmias ventriculares e morte súbita. Dados locais quanto às características clínicas dos pacientes com padrão eletrocardiográfico (ECG) típico avaliados por estudo eletrofisiológico (EEF) são escassos. Objetivo: Avaliar pacientes com padrão ECG sugestivo de SBr encaminhados para EEF em um centro especializado. Métodos: Estudo de coorte de casos encaminhados para EEF por padrão ECG compatível com SBr, entre janeiro de 1998 e março de 2017. Resultados: Dos 5506 procedimentos, 35 (0,64%) foram para investigação de SBr. Vinte e cinco (71,42%) eram homens. Idade média 43,89 ± 13,1 anos. Apresentação ECG foi tipo I em 22 casos (62,85%), tipo II em 12 (34,30%) e tipo III em 1 (2,85%). Vinte e três (65,7%) eram assintomáticos, 6 (17,14%) apresentavam palpitações, 5 (14,3%) síncope, 3 (8,6%) história familiar de morte súbita. Estudo eletrofisiológico induziu taquiarritmias ventriculares em 16 casos (45,7%), sendo o período refratário ventricular médio de 228 ± 36 ms. Utilizou-se ajmalina/procainamida em 11 casos (31,4%), sendo o padrão ECG transformado em tipo I em 7 (63,6%). Dezesseis casos (45,7%) receberam cardiodes fibrilador (CDI). Em seguimento médio de 5 anos, 1 dos 16 pacientes (6,25%) com CDI teve terapia apropriada para fibrilação ventricular. Nenhuma morte foi registrada. Outras arritmias ocorreram em 4 (11,4%) casos. Conclusões: Homens são maioria, sendo o padrão ECG tipo I a principal indicação de EEF. Droga classe IA possui alta taxa de conversão do padrão ECG. A taxa de eventos no CDI foi de 6%. (Arq Bras Cardiol. 2018; [online].ahead print, PP.0-0)


Subject(s)
Humans , Male , Female , Adult , Registries/statistics & numerical data , Defibrillators, Implantable , Brugada Syndrome/surgery , Time Factors , Cohort Studies , Tachycardia, Ventricular/etiology , Electrocardiography , Electrophysiology , Brugada Syndrome/complications , Brugada Syndrome/mortality , Kaplan-Meier Estimate
4.
Rev. bras. cir. cardiovasc ; 32(6): 492-497, Nov.-Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-897955

ABSTRACT

Abstract Introduction: Chronic stimulation of the right ventricle with pacemaker is associated with ventricular dyssynchrony and loss of contractility, even in subjects without previous dysfunction. In these patients, there is a debate of which pacing site is less associated with loss of ventricular function. Objective: To compare pacemaker-induced dyssynchrony among different pacing sites in right ventricular stimulation. Methods: Cross-sectional study of outpatients with right ventricle stimulation higher than 80% and preserved left ventricular ejection fraction. Pacing lead position (apical, medial septum or free wall) was assessed through chest X-rays. Every patient underwent echocardiogram to evaluate for dyssynchrony according to CARE-HF criteria: aortic pre-ejection time, interventricular delay and septum/posterior wall delay on M mode. Results: Forty patients were included. Fifty-two percent had apical electrode position, 42% mid septum and 6% free wall. Mean QRS time 148.97±15.52 milliseconds. A weak correlation between the mean QRS width and pre-aortic ejection time (r=0.32; P=0.04) was found. No difference in QRS width among the positions could be noted. Intraventricular delay was lower in apical patients against mid septal (34.4±17.2 vs. 54.3±19.1 P<0.05) - no difference with those electrode on the free wall. No difference was noted in the pre-aortic ejection time (P=0.9). Conclusion: Apical pacing showed a lower interventricular conduction delay when compared to medial septum site. Our findings suggest that apical pacing dyssynchrony is not ubiquitous, as previously thought, and that it should remain an option for lead placement.


Subject(s)
Humans , Male , Female , Aged , Pacemaker, Artificial/adverse effects , Cardiac Pacing, Artificial/adverse effects , Ventricular Dysfunction, Right/etiology , Arrhythmias, Cardiac/physiopathology , Stroke Volume , Echocardiography , Cardiac Pacing, Artificial/methods , Cross-Sectional Studies , Ventricular Function, Right , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Left/etiology , Electrocardiography , Heart Ventricles , Myocardial Contraction
SELECTION OF CITATIONS
SEARCH DETAIL